Harrison Roper's Blog (87)

UMPI turbine update-

After many months, the "live wind data" page of the UMPI turbine is reporting something! But the turbine is still not generating power.Iin a 12 mph wind,  rotor rpm and generator rpm are zero, and power output is MINUS .4 kWh. That's 400 watts of grid power, being used to keep the machine working. At least something is working, and there is an effort to get it all…

Continue

Added by Harrison Roper on September 19, 2012 at 1:36pm — 1 Comment

UMPI turbine

The UMPI turbine website reports it down for repairs, with a new power  figure: 400,221 kWH produced since last mid-November.  The data reporting is also under repair, as it had been for months. 

    Harry Roper   Houlton/Danforth

Added by Harrison Roper on August 16, 2012 at 9:37am — 3 Comments

New UMPI data - same old story

As of today (July 5, 2012) the UMPI turbine website reports it has  generated 379,171 kwH "since mid-November". That is 223 days; at 14,000 kwH per day "installed" capacity, that's a Capacity Factor of .118, about the same as the previous reports. No other new information is posted. As before, the site declares the full-data reporting software continues to need "fine tuning".

   The turbine was shut down for 210 days before last November's fresh start-up. That's 223 days of…

Continue

Added by Harrison Roper on July 5, 2012 at 4:21pm — 3 Comments

UMPI turbine website reports new total

Wednesday, June 27, 2012 -The UMPI turbine website just posted a new production figure: 374,690 kWh since "mid-November".

That's 217 days, or an average of 1727 kWh per day.  The "installed capacity" is 14,400 kWh per day, so that's a Capacity Factor of  11.99%.  No other new information is posted - the "full turbine informaiton" software is still not working.

Harry Roper   Houlton/Danforth

Added by Harrison Roper on June 27, 2012 at 3:39pm — 5 Comments

Stetson II and Harvard

It is good that attention is being paid to Harvard's purchased interest in Stetson II. Here are some hard facts - let's see if Harvard cites these uncomfortable figures:

  According to FERC's quarterly summaries, Stetson II (when construction was completed) produced 10 GWH in the third quarter of 2010 and 20 GWH in the fourth quarter of 2010.

The installed capacity of Stetson II is 57 GWH per quarter. That's 30 GWH produced for the half year; installed capacity for the period…

Continue

Added by Harrison Roper on June 27, 2012 at 10:44am — 2 Comments

UMPI turbine's latest power production data

Today (July 20, 2012) the UMPI wind turbine site reported  actual power produced since mid-November of  2011 at 364,689 KWH. That's 210 days, and an average 1736 KWH per day. Divide that average by the "installed capacity" of 14,000 KWH per day and you get .124. This is called the "capacity factor"; capacity factor is seldom mentioned by wind promoters. It means the turbine has been working at one eighth  (12.6%) of its potential since it was repaired in mid-November of 2011.  This, for an…

Continue

Added by Harrison Roper on June 20, 2012 at 11:20am — No Comments

UMPI turbine website reports new total

Today the UMPI turbine website reports an update of its ouptut; it generated 355.286 KWH since mid November. That's about six months, or about 183 days. The turbine's "installed capacity" for that period is 600 KW times 24 hours times 183 days equals 2,635,200 KWH. Divide the installed capacity into the actual power produced yields a paltry Capacity Factor of .134 . The previous Capacity  Factor, on May 29 was .126. An optomist would say things are improving. I think a realist would say…

Continue

Added by Harrison Roper on June 10, 2012 at 9:19pm — No Comments

FERC quarterly summaries back on website

After disappearing for a day or so, the FERC website has the quarterly summaries posted again.

Added by Harrison Roper on June 8, 2012 at 4:17pm — No Comments

UMPI website reports 190 days of power - and 12.6% of installed capacity.

The UMPI wind turbine has a capacity of 600 kw, or 14,400 kwH per day in perfect wind.  Today the website reports 345,400 kwH "since mid-November".  That's 190 days, and the power that was produced averaged 1818 kwH per day. Divide 1818 by 14,400 and you get a 12.6 %  Capacity Factor. For this turbine in this location, 12.6%  Capacity Factor is about average.  On the 14th of this month, the turbine's third anniversary, I calculated a Capacity Factor of 8.9%, including a 210-day period of…

Continue

Added by Harrison Roper on May 29, 2012 at 3:04pm — No Comments

Despite windy day, Stetson turbines stationary

Today my wife and I were at our camp, which is on the hill across Upper Hot Brook Lake from the dozens of Stetson I and II turbines. There was a good wind all afternoon, with some whitecaps on the lake. When we  arrived at about 12:30 pm, ten of the eleven visible Stetson II turbines were turning, at about 23 rpm.  Later in the afternoon (down at the lake) we saw only Stetson II turning, and at 3:00 to 4:30 none of the 30 visible turbines, including all of Stetson II and about 17 of Stetson…

Continue

Added by Harrison Roper on May 17, 2012 at 8:31pm — No Comments

Reply to Hart Daley

Hello Hart - Here is a partial list:

Lincoln Lakes (First Wind)  Rollins   Evergreen Wind Power III, LLC

Washington County -Stetson I (First Wind) Evergreen Wind Power V, LLC

washington County -Stetson II (First Wind) Stetson Wind, LLC

Mars Hill - (First Wind) Evergreen Wind Power, LLC

Kibby - TransCanadian Maine Wind Development, Inc.

Carthage - Canton Mountain Wind, LLC

Oakfield - (First Wind; not yet under construction) will be Evergreen…

Continue

Added by Harrison Roper on May 15, 2012 at 4:48pm — 2 Comments

FERC website maybe about to update; UMPI posts small change

The quarterly summary and spreadsheet pages of the FERC website are shut down as of 11:00 this morning (5/14).  I am hoping this means they are being updated with 1st quarter 2012 data. (The quarter ended March 31, 44 days ago.) 

  Also, the UMPI turbine was erected exactly 3 years ago.  I plan to do a summary of its power production , capacity factor, and reliability record and I will post it soon.

  One sentence was changed on the website: a re-wording of the explanation of…

Continue

Added by Harrison Roper on May 14, 2012 at 11:28am — No Comments

umpi website posts new ouptut data

The UMPI website has posted the turbine's power output for the past week, Friday May 4 - Friday May 11:  12,324 KWh was generated by its 600 kw turbine in tha past week.  12,324 KWh divided by the 100,800 KWh per week installed capacity (600 KW X 7 days X 24 hours ) gives a Capacity Factor of 12.2 %,  slightly less than than the average 12.7 CF for the previous 164 days. Before mid-November, it was non-operative for 164 continuous days. 

I am hoping UMPI will continue posting a weekly…

Continue

Added by Harrison Roper on May 11, 2012 at 3:56pm — 4 Comments

UMPI turbine's twin completes its third year

  The Mark Richey Woodworking Co in Newburyport, MA put up a 600 KW turbine at its plant in March  of 2009, accompanied by much publicity, etc.   It is the same size (600 KW) and manufacturer as UMPI's turbine, which went up two months later in the same year.  There is a website that reports steadily on the Mark Richey Co. turbine's output;  UMPI's website reports sporatically, at best.

Google:  Mark Richey Woodworking.

   As far as I know the Mark Richey's Co's turbine has not…

Continue

Added by Harrison Roper on May 8, 2012 at 3:39pm — No Comments

Mark Richey Co's Newburyport, MA turbine posts 13.4 Capacity factor for three years of production

I figure a 3-year13.4% Capacity Factor for the Mark Richey Woodworking Co's turbine, which is identical to UMPI's. They both went into use three years ago.  The M. Richey Co.'s turbine and website are much more reliable than UMPI's, and Newburyport is on the MA coast, not inland. Nevertheless.....

Harrison Roper

Houlton/Danforth

Added by Harrison Roper on May 8, 2012 at 3:38pm — No Comments

UMPI turbine posts new data

The UMPI turbine site has just posted a new power production figure::

Since mid-November of 2011, the turbine produced 302,150 kWh for UMPI.  

That's 164 days, an average of 1,842 kWh per day.

302,150 kWh divided by 164 gives an average of 1,842 kwh per day produced since it was fixed.  

It is a 600 kw turbine; 600 kw X 24 hours is 14,400 kWh per day "installed capacity".  

1,842 kWh (recorded average daily power production) divided by 14,400 kWh (installed…

Continue

Added by Harrison Roper on May 4, 2012 at 4:01pm — 8 Comments

UMPI website reports a miniscule Capacity Factor for past 140 days

  The UMPI turbine website is reporting power production the past 140 days:  290,516 kWh "since mid-November" until April 6.  I calculate: 140 days at 600 Kw capacity and 24 hours per day comes to "installed capacity" of 20,160,000 kWh for that period; 290,516 kWh actual power production divided by the installed capacity gives a MINISCULE .014 Capacity Factor.  This compares very poorly to most Maine wind farms' CF, which range from .24 to .41 CF for the same period.

The site…

Continue

Added by Harrison Roper on April 10, 2012 at 12:35pm — 1 Comment

FERC 1st quarter '12 spreadsheets are posted

FERC has posted some speadsheets of data on generators' power sales for the 1st quarter of 2012.  Ths list is short and will grow as more data reports come in. In a quick scan, I did not spot any Maine wind facilities' data. The quarterly summaries will be posted in a couple of weeks.

Harrison Roper  Houlton/Danforth, ME 

Added by Harrison Roper on April 6, 2012 at 1:55pm — No Comments

Vinalhaven energy price

I wold like to know what Vinalhaven's  energy price per kwh was  before the turbines, and what it is now.

Thank you - Harry Roper   Houlton/Danforth

207-532-3797

Added by Harrison Roper on April 4, 2012 at 4:00pm — 1 Comment

UMPI website reports it's working.

As of March 15 the UMPI turbine website reported the turbine, after a "down" period of months for repair,  had been generating power for 126 days;  "180,240 kWh since 2nd week of November".  There is no other information - the software needs "fine tuning",  

Operating perfectly in ideal wind  the UMPI turbine is "rated" to  generate 600 kW, or 14,400 kWh per day

 It has been in operation 126 days since early November. 

14,400 kwh X 126 = 1,814,400 kwh. This woud be 100%…

Continue

Added by Harrison Roper on March 19, 2012 at 11:20am — No Comments

 

Maine as Third World Country:

CMP Transmission Rate Skyrockets 19.6% Due to Wind Power

 

Click here to read how the Maine ratepayer has been sold down the river by the Angus King cabal.

Maine Center For Public Interest Reporting – Three Part Series: A CRITICAL LOOK AT MAINE’S WIND ACT

******** IF LINKS BELOW DON'T WORK, GOOGLE THEM*********

(excerpts) From Part 1 – On Maine’s Wind Law “Once the committee passed the wind energy bill on to the full House and Senate, lawmakers there didn’t even debate it. They passed it unanimously and with no discussion. House Majority Leader Hannah Pingree, a Democrat from North Haven, says legislators probably didn’t know how many turbines would be constructed in Maine if the law’s goals were met." . – Maine Center for Public Interest Reporting, August 2010 https://www.pinetreewatchdog.org/wind-power-bandwagon-hits-bumps-in-the-road-3/From Part 2 – On Wind and Oil Yet using wind energy doesn’t lower dependence on imported foreign oil. That’s because the majority of imported oil in Maine is used for heating and transportation. And switching our dependence from foreign oil to Maine-produced electricity isn’t likely to happen very soon, says Bartlett. “Right now, people can’t switch to electric cars and heating – if they did, we’d be in trouble.” So was one of the fundamental premises of the task force false, or at least misleading?" https://www.pinetreewatchdog.org/wind-swept-task-force-set-the-rules/From Part 3 – On Wind-Required New Transmission Lines Finally, the building of enormous, high-voltage transmission lines that the regional electricity system operator says are required to move substantial amounts of wind power to markets south of Maine was never even discussed by the task force – an omission that Mills said will come to haunt the state.“If you try to put 2,500 or 3,000 megawatts in northern or eastern Maine – oh, my god, try to build the transmission!” said Mills. “It’s not just the towers, it’s the lines – that’s when I begin to think that the goal is a little farfetched.” https://www.pinetreewatchdog.org/flaws-in-bill-like-skating-with-dull-skates/

Not yet a member?

Sign up today and lend your voice and presence to the steadily rising tide that will soon sweep the scourge of useless and wretched turbines from our beloved Maine countryside. For many of us, our little pieces of paradise have been hard won. Did the carpetbaggers think they could simply steal them from us?

We have the facts on our side. We have the truth on our side. All we need now is YOU.

“First they ignore you, then they laugh at you, then they fight you, then you win.”

 -- Mahatma Gandhi

"It's not whether you get knocked down: it's whether you get up."
Vince Lombardi 

Task Force membership is free. Please sign up today!

Hannah Pingree on the Maine expedited wind law

Hannah Pingree - Director of Maine's Office of Innovation and the Future

"Once the committee passed the wind energy bill on to the full House and Senate, lawmakers there didn’t even debate it. They passed it unanimously and with no discussion. House Majority Leader Hannah Pingree, a Democrat from North Haven, says legislators probably didn’t know how many turbines would be constructed in Maine."

https://pinetreewatch.org/wind-power-bandwagon-hits-bumps-in-the-road-3/